Model: AX-704. Welding current checker
[HI][GO][LO]judgment indication installed digital comparator
● Measurement range: both L and R 000A~999A
● Both L and R 3 digit digital indication (7 segments LED indication)
● Measurement speed: about 100msec. (max)
● Simultaneously NG alarm output
Specifications
Measuring range | 000A~999A both L and R |
---|---|
Measured value | Effective value of the measuring range conversion |
Display | Both L and R:3-digit digital display (7-segment LED display) |
Measurement accuracy | Within ±2% of full scale |
Measuring speed | about 100msec. (max.) |
Determine current range | Absolute value mode:000A~999A both L and R (Digital switch, upper and lower limit) % Mode:-99.9%~+99.9% both L and R (Digital switch, upper and lower limit) |
Measurement trigger level | Both L and R:000A~399A (Setting potentiometer) |
Setting the continuous alarm | 0~19 times |
Setting the output shift | 0~99 |
Measurement sensor | Measurement sensor both L and R pickup coil |
Buzzer output | ON when NG alarm output simultaneously |
External interface | (Connector input and output signal shift) Isolation |
Measurement start | |
Both L and R:NG (Pulse output) | |
(Alarm input and output signal connector) Isolation | |
Alarm reset input | |
(Control input signal) Isolation | |
Measurement start | |
Alarm reset | |
(Control output signal) Isolation | |
NG shift | |
Shift GO | |
Total GO | |
End of measurement | |
Simultaneous NG alarm relay junction output | |
Operation condition | [Temp.] +5℃~+40℃ [Humidty] less than 85% |
Power supply | AC85V~264V, 50/60Hz, about 40VA |
Outer dimension | 333 (W) ×99 (H) ×300 (D) mm (excluding protruding parts such as rubber legs, etc.) |
Weight | about 3.5kg |
The Outline
Model AX-704 welding current checker digital displayed welding current both L and R sides when weld lead line of resistor both sides at the same time, and indicates to judge bounds pair limit value setup beforehand for [HI] [GO] [LO] with installing digital comparator.
It equips number of total GO, a function of alert for NG, setup shift number of judgment output and external output.